Brief introduction to the function introduction and installation method of the booster pump

The gas booster pump series is a two-stage booster pump that can increase the pressure of very low pressure gas to a very high pressure. The driving pressure is ≤7bar, the pressure of the gas input port is 0.5-10 bar, and the maximum can be increased to 90Mpa. The reversing mode of this series of pumps is exactly the same as that of the N series. The whole pump is made of aluminum alloy and stainless steel. In the gas drive section of the pump, the series requires a lubricated gas to lubricate the seals and other internal parts. The pump has a drive piston diameter of 160 mm. The gas booster pump series is a single-stage booster pump to meet the needs. The input pressure of the pressure gas input port requires a certain degree of preload, and the pre-increased pressure varies depending on the maximum pressure of the gas booster pump picture. The maximum pressure can be increased to 80Mpa.

The gas booster pump H series uses a single air-controlled unbalanced gas distribution valve to achieve reciprocating motion of the pump, all made of aluminum alloy and stainless steel. All seals are imported high-quality products, the maximum design drive pressure is 10bar, in order to ensure the life of the pump, it is recommended to drive the pressure <8bar. The pumps have a drive piston diameter of 160 mm and are single-acting pumps, all with single-acting pumps with exhaust cooling. The gas booster pump N series is a two-stage booster pump, which can increase the pressure of very low pressure gas to a very high pressure. The driving pressure is ≤7bar, the pressure of the gas inlet is 0.5-10 bar, and the maximum can be increased to 90Mpa. The reversing mode of this series of pumps is exactly the same as that of the B series, and the flow rate is doubled compared with the B type.

Mechanical installation of booster pump

When installing the tap water booster pump, be sure to install it horizontally or vertically in the “Installation Mode” display. The direction of the water flow should be the same as the direction of the arrow on the pump body, and install it as far as possible from the lowest position of the water level. For ease of use and maintenance, a valve should be installed on the pump inlet line. When the pumped liquid level is lower than the upper end surface of the impeller of the pump or the shaft of the pump, the pump should be equipped with a check valve, and the outlet end is connected with a three-way for water diversion. The pump should be filled with water for the first time. Tighten the plug. The pipe connection should be tight, especially if the water inlet pipe cannot leak, otherwise the pump head will be lowered or the water will not be pumped. Do not rotate for a long time before the water is introduced into the pump chamber to avoid damage to the seals.

A safety protector is installed in the motor coil. When the pump fails or does not pump water, the motor can be automatically disconnected when the temperature rises above the specified value. After the temperature rise of the motor is removed, the motor can automatically resume operation. The booster pump motor is a capacitor-operated motor. The direction of rotation of the pump is adjusted when it leaves the factory. If you need to replace the capacitor or re-wire, please press the arrow on the pump body to mark the wiring. To ensure safe use, you must use a three-wire safety socket with a grounding wire. When the pump is leaking, immediately stop the machine to prevent internal leakage. If the water is connected to the motor, replace the mechanical seal. Check if the power is on. Use the power supply voltage to match the operating voltage of the pump. If a and b are normal, please remove the pump, open the pump cover, remove the foreign matter in the pump, and then install the pump cover, and adjust it to normal.

When the pump is not pumping water, the pump is installed on the water pipe. If the tap water level is below the plane (horizontal installation) or center line (vertical installation) of the impeller of the pump, the power should be turned off at this time, and the water level of the tap water should rise more than When the impeller plane or center line is turned on, turn on the power to avoid damage to the mechanism (automatic type does not need to be turned off). When the pump is used to pump well water, please check whether the water inlet pipe is leaking; if there is not enough water in the pump cavity, it should be filled with water, and the suction stroke is too high, and it should be adjusted properly. Check if the inlet and outlet pipe diameter is too small or blocked. After the automatic type of use for a period of time, automatic failure may occur, mainly due to long-term precipitation of metal such as steel rust in the water pipe. After the power is turned off, the switch is removed, the upper screw is unscrewed, the plastic piece is taken out and cleaned, and then , according to the original reset, debugging is normal, you can reuse.

Global hardware network

Concerned about surprises

Tag: Booster pump Installation method Inlet pipe Installation method Function introduction

Previous: Understanding the basics of energy converters Next: How to choose screw wire?

Spherical Bearing

Spherical Bearing,Sliding Type Spherical Bearing,Spherical Rotating Steel Bearing

Rubber Water Stop,Elastomeric Bearing Pad Co., Ltd. , http://www.chsteelprofile.com